• Eco Tm Slide 01
  • Eco Tm Slide 02

    SR

    Insurance Approved Security Shutters

    The Secure Level 1 extruded aluminium slat is for higher security domestic use and medium security for commercial, retail and counter/cabinet applications. For applications up to 4000mm wide when electrically operated.

    Unlike other certificated shutters, this shutter uses a 38mm double-walled extruded aluminium slat, which coils very tightly into a range of compact boxes (165mm-250mm), minimising their visual impact.

    • Secure - locking is provided automatically from the motor and bottom rail shoot locks or bullet locks to the side guides
    • Compact - housings from 165mm-250mm dependent on shutter height

    Certifications

    • BSEN 13241-1- : 2003

    Tech Info

    • Min width: 900mm
    • Max size: 3m w x 4m h
    • Max area: 12m2
    • Weight: 8kg/m2

    Roller Head Plate Sizes

    • Height 1000mm > 1500mm -> 165mm
    • Height 1600mm > 1900mm -> 180mm
    • Height 2000mm > 2600mm -> 205mm
    • Height 2600mm > 4000mm -> 250mm

    Standard Specification

    • 38mm extruded aluminium curtain
    • Guide rails 70mm x 27mm
    • Bottom rail lock or side guide rail locks
    • Guardian Safe 24 volt control unit (electric operation)
    • Anti-fall device
    • Hold to run operation (electric operation)
    • Plug-in operation (electric operation)

    Colour Finish

    • Polyester powder coat finish to BS colour or RAL number
    • Range of corporate branding packages including full colour graphics
    • Mill finish
    • Galvanised

    General Options

    Protective Bollards

    We offer a range of protective bollards to prevent collision damage to your door set. Information on request.
    • Protective Bollards

      We offer a range of protective bollards to prevent collision damage to your door set. Information on request.

      Protective Bollards

      Angle Protection

      Floor fixed heavy duty angle protection.
      • Angle Protection

        Floor fixed heavy duty angle protection.

        Angle Protection

        Coil Casing

        Casing to cover the rear of the coil and motor.
        • Coil Casing

          Casing to cover the rear of the coil and motor.

          Coil Casing

          Fitting Configurations

          • Face fit
          • Reveal fit

          Security

          Security Gates

          High level of security for sensitive areas designed to be fitted on the inside of roller shutters and sectional doors.
          • Security Gates

            High level of security for sensitive areas designed to be fitted on the inside of roller shutters and sectional doors.

            Security Gates

            Pinlocks

            For additional security, pin locks can be added to a range of shutters. The lock fits into a casting on the roller shutters guide section. The pin fits through this casting and the roller shutter curtain to stop the curtain from attempts at lifting it. For electric doors a safety interlock is recommended to avoid accidentally attempting to open the shutter when locked.
            • Pinlocks

              For additional security, pin locks can be added to a range of shutters. The lock fits into a casting on the roller shutters guide section. The pin fits through this casting and the roller shutter curtain to stop the curtain from attempts at lifting it. For electric doors a safety interlock is recommended to avoid accidentally attempting to open the shutter when locked.

              Pinlocks

              Keyswitch Lockbox

              Security box to protect externally mounted keyswitches.
              • Keyswitch Lockbox

                Security box to protect externally mounted keyswitches.

                Keyswitch Lockbox

                Ground Locks

                Locks with interlock safety that fit into the ground and and are fixed with a shutter padlock.
                • Ground Locks

                  Locks with interlock safety that fit into the ground and and are fixed with a shutter padlock.

                  Ground Locks

                  Anti-Tamper Controller

                  Interfaces directly with a key switch, the shutter is made inoperable if the key switch is attacked by vandals or thieves. The system can also be linked to a burglar alarm further increasing security measures. Has a low voltage control circuit removing the risk of electric shocks, making the product ideal for use in public areas.
                  • Anti-Tamper Controller

                    Interfaces directly with a key switch, the shutter is made inoperable if the key switch is attacked by vandals or thieves. The system can also be linked to a burglar alarm further increasing security measures. Has a low voltage control circuit removing the risk of electric shocks, making the product ideal for use in public areas.

                    Anti-Tamper Controller

                    Anti-Ram Bollards

                    A highly visual and effective deterrent against frontal vehicle assault and accidental damage.
                    • Anti-Ram Bollards

                      A highly visual and effective deterrent against frontal vehicle assault and accidental damage.

                      Anti-Ram Bollards

                      Bottom Rail Lock

                      ILS lock that connects to bottom bar and extends into guides for extra security.
                      • Bottom Rail Lock

                        ILS lock that connects to bottom bar and extends into guides for extra security.

                        Bottom Rail Lock

                        Safety

                        Warning Lights

                        Warning lights to alert users when doors are in operation.
                        • Warning Lights

                          Warning lights to alert users when doors are in operation.

                          Warning Lights

                          Battery Backup

                          We provide a range of battery backup or UPS systems (uninterrupted power supplies) to ensure the door system will remain operational during times when the power is lost (limited amount of cycles before battery will be drained, battery backups require maintenance).
                          • Battery Backup

                            We provide a range of battery backup or UPS systems (uninterrupted power supplies) to ensure the door system will remain operational during times when the power is lost (limited amount of cycles before battery will be drained, battery backups require maintenance).

                            Battery Backup

                            Reflected Photoelectric Cell

                            This unit beams and reflects an infra red signal, if the beam is broken the door will stop or return upwards.
                            • Reflected Photoelectric Cell

                              This unit beams and reflects an infra red signal, if the beam is broken the door will stop or return upwards.

                              Reflected Photoelectric Cell

                              S/R Photoelectric Cell

                              This unit has two sensors which send a constant signal between them. Should the beam be broken the door will stop or return to the open position.
                              • S/R Photoelectric Cell

                                This unit has two sensors which send a constant signal between them. Should the beam be broken the door will stop or return to the open position.

                                S/R Photoelectric Cell

                                Safety Pressure Edge Wired

                                Installed on the door's bottom edge, the sensor when activated will return the door to the open position.
                                • Safety Pressure Edge Wired

                                  Installed on the door's bottom edge, the sensor when activated will return the door to the open position.

                                  Safety Pressure Edge Wired

                                  Operation & Controls

                                  Activ8

                                  Motion sensor.
                                  • Activ8

                                    Motion sensor.

                                    Activ8

                                    Keypads

                                    A range of keypads for PIN entry.
                                    • Keypads

                                      A range of keypads for PIN entry.

                                      Keypads

                                      Group Control

                                      Allows multiple doors to be controlled with a single controller.
                                      • Group Control

                                        Allows multiple doors to be controlled with a single controller.

                                        Group Control

                                        Fire Brigade Switch

                                        This specialised key switch enables authorised fire service personnel to quickly operate the door in the event of a fire or other emergency situation.
                                        • Fire Brigade Switch

                                          This specialised key switch enables authorised fire service personnel to quickly operate the door in the event of a fire or other emergency situation.

                                          Fire Brigade Switch

                                          Push Buttons

                                          We offer a range of push button controls.
                                          • Push Buttons

                                            We offer a range of push button controls.

                                            Push Buttons

                                            Biometric Controls

                                            Fingerprint reader control unit for extra security.
                                            • Biometric Controls

                                              Fingerprint reader control unit for extra security.

                                              Biometric Controls

                                              Smoke & Heat Detector

                                              Will send a signal to close upon detecting smoke or excessive heat.
                                              • Smoke & Heat Detector

                                                Will send a signal to close upon detecting smoke or excessive heat.

                                                Smoke & Heat Detector

                                                Access Control Relay

                                                Card reader access control.
                                                • Access Control Relay

                                                  Card reader access control.

                                                  Access Control Relay

                                                  RFID Radio Controls

                                                  We offer a range of RFID activation options. Activation at 1.5M, 3M and 5M ranges from the receiver.
                                                  • RFID Radio Controls

                                                    We offer a range of RFID activation options. Activation at 1.5M, 3M and 5M ranges from the receiver.

                                                    RFID Radio Controls

                                                    Standard Fire Door Interface Panel

                                                    Supplied with all electric single phase shutters the unit transforms 240V power into safe 24V ensuring safety for the operator at all times. The unit is compliant with the Low Voltage Directive (LVD) The LED on the front of the panel has a colour code as follows:

                                                    • Amber when mains power is detected
                                                    • Green when opening the shutter
                                                    • Red when the shutter is closing
                                                    The control unit can also be connected via a continuous volt free signal to a fire alarm to open or close the shutter when the alarm is activated
                                                    • Standard Fire Door Interface Panel

                                                      Supplied with all electric single phase shutters the unit transforms 240V power into safe 24V ensuring safety for the operator at all times. The unit is compliant with the Low Voltage Directive (LVD) The LED on the front of the panel has a colour code as follows:

                                                      • Amber when mains power is detected
                                                      • Green when opening the shutter
                                                      • Red when the shutter is closing
                                                      The control unit can also be connected via a continuous volt free signal to a fire alarm to open or close the shutter when the alarm is activated

                                                      Standard Fire Door Interface Panel

                                                      • Remote Control - Hold to run
                                                      • Remote Control - One touch operation
                                                      • GSM Access
                                                      • Software/network connection
                                                      • Wind sensor
                                                      • Sun sensor
                                                      • Fire alarm activation

                                                      Operation

                                                      • Manual operation
                                                      • Rod crank operation
                                                      • Belt operation

                                                      Peace of Mind Warranties

                                                      All Guardian products are guaranteed against defect of material or workmanship by Guardian Doors, subject to correct maintenance and operation, for a period of 12 months from the date of installation. We offer extended warranties for up to 5 years with an agreed maintenance contract. Call us on 0800 7836602 for more details.

                                                      Business Hours

                                                      Monday - Friday
                                                      8:00 to 17:00
                                                      Saturday - Sunday
                                                      Closed

                                                      Our 24 hour emergency repair service is available every day - call 0800 7836602

                                                      Privacy Policy & Cookies

                                                      This website uses cookies that are necessary to its functioning and required to achieve the purposes illustrated in the privacy policy. By accepting this OR continuing to browse, you agree to our privacy policy.