• EI60-EW60 Fire Shutter
  • EI60-EW60 Fire Shutter
  • EI60-EW60 Fire Shutter

    EI60-EW60

    60 min Insulation and Integrity rated fire resistant roller shutters

    Fire-resistant roller shutters offer an excellent solution for closing off or compartmentalising premises such as government agencies, shopping centres and, of course, various industrial applications in a fire-safe manner.

    Partly thanks to its high fire-resistance of 60 minutes (in accordance with the El(1) requirement) based on two-sided testing in accordance with EN1634–1.

    The fire-resistant roller shutter is also available with a certified liquid barrier, explosion-proof (ATEX) components and is even available entirely ATEX marked, so that the shutter provides an excellent solution for areas where hazardous substances are stored.

    Explanation of Fire Rating Symbols

    Integrity & Insulation
    E - Integrity This is the ability of a test component to stop fire from spreading to an unexposed side as a result of penetration of flames or smoke.
    I - Insulation This is the ability of a test component to restrict the temperature rise of the non-heated side to below specified levels during the fire, which is not more than +140°C up to +180°C.
    Integrity & Radiation Reduction
    E - Integrity This is the ability of a test component to stop fire from spreading to an unexposed side as a result of penetration of flames or smoke.
    W – Reduction of thermal radiation This is the ability of a test component to resist fire exposure on one side only, so as to reduce the probability of the transmission of fire as a result of significant radiated heat either through the element or from its unexposed surface to neighbouring objects.

    All of the above parameters are followed by a time limit in minutes. The number after a given symbol shows the time the performance criteria is fulfilled during a standardised fire test, eg. EI120, EW60, etc.


    Certifications

    • BS EN 1634-1:2014
    • BS EN 1634-3:2004

    Tech Info

    • Max width: 10000mm
    • Max height: 10000mm
    • Max area: 50m2

    Curtain Construction

    The door curtain of the fire-resistant roller shutter is constructed from 60mm thick galvanised, double walled steel slats. The slats consist of two 0.80mm thick profiled, galvanised steel sheets, filled with mineral insulation. The underside of the curtain is finished with a galvanised steel profile, attached to the bottom slat of the curtain by steel rivets. The slats are finished with galvanised steel end locks on both sides. The slats are fitted with a unique click-system that allows the slats to be mounted and unmounted at a 90 degree angle.

    Side Guide

    The side guides are constructed from galvanised steel guides and a corner section, which are both fitted with intumescent material.

    Movement System

    The movement system is composed of two galvanised steel brackets on which the tube is mounted. The brackets are fastened to the wall with bolts and locking plates.

    To ensure the stability of the movement system, a galvanised steel diagonal brace is fitted to the ends of the brackets. The drive shaft that rolls the curtain up and down is located between the brackets.

    The fire resistant roller shutters come standard with a 400V chain wheel motor. If the dimensions of the fire resistant roller shutter are small, a 230V tubular motor can be fitted. The roller shutters are fitted with a control unit and safety brake as standard. If the fire-resistant roller shutter is fitted with a chain wheel motor, an optional fail-safe drive system can be installed to close the shutter in a controlled manner using gravity in the event of power failure. For fire-resistant roller shutters with a tubular motor, an emergency backup battery can be optionally installed to allow the shutter to continue operating in the event of power failure.

    Colour Finish

    • Polyester powder coat finish to BS colour or RAL number
    • Range of corporate branding packages including full colour graphics
    • Stainless steel

    General Options

    Protective Bollards

    We offer a range of protective bollards to prevent collision damage to your door set. Information on request.
    • Protective Bollards

      We offer a range of protective bollards to prevent collision damage to your door set. Information on request.

      Protective Bollards

      Angle Protection

      Floor fixed heavy duty angle protection.
      • Angle Protection

        Floor fixed heavy duty angle protection.

        Angle Protection

        Fitting Configurations

        • Face fit
        • Reveal fit

        Safety

        Warning Lights

        Warning lights to alert users when doors are in operation.
        • Warning Lights

          Warning lights to alert users when doors are in operation.

          Warning Lights

          Battery Backup

          We provide a range of battery backup or UPS systems (uninterrupted power supplies) to ensure the door system will remain operational during times when the power is lost (limited amount of cycles before battery will be drained, battery backups require maintenance).
          • Battery Backup

            We provide a range of battery backup or UPS systems (uninterrupted power supplies) to ensure the door system will remain operational during times when the power is lost (limited amount of cycles before battery will be drained, battery backups require maintenance).

            Battery Backup

            Reflected Photoelectric Cell

            This unit beams and reflects an infra red signal, if the beam is broken the door will stop or return upwards.
            • Reflected Photoelectric Cell

              This unit beams and reflects an infra red signal, if the beam is broken the door will stop or return upwards.

              Reflected Photoelectric Cell

              S/R Photoelectric Cell

              This unit has two sensors which send a constant signal between them. Should the beam be broken the door will stop or return to the open position.
              • S/R Photoelectric Cell

                This unit has two sensors which send a constant signal between them. Should the beam be broken the door will stop or return to the open position.

                S/R Photoelectric Cell

                Safety Pressure Edge Wired

                Installed on the door's bottom edge, the sensor when activated will return the door to the open position.
                • Safety Pressure Edge Wired

                  Installed on the door's bottom edge, the sensor when activated will return the door to the open position.

                  Safety Pressure Edge Wired

                  • Illuminated status indicators

                  Operation & Controls

                  Mushroom Push Button

                  Hand/foot switch station with a large dome head.
                  • Mushroom Push Button

                    Hand/foot switch station with a large dome head.

                    Mushroom Push Button

                    Fire Brigade Switch

                    This specialised key switch enables authorised fire service personnel to quickly operate the door in the event of a fire or other emergency situation.
                    • Fire Brigade Switch

                      This specialised key switch enables authorised fire service personnel to quickly operate the door in the event of a fire or other emergency situation.

                      Fire Brigade Switch

                      Push Buttons

                      We offer a range of push button controls.
                      • Push Buttons

                        We offer a range of push button controls.

                        Push Buttons

                        Biometric Controls

                        Fingerprint reader control unit for extra security.
                        • Biometric Controls

                          Fingerprint reader control unit for extra security.

                          Biometric Controls

                          Access Control Relay

                          Card reader access control.
                          • Access Control Relay

                            Card reader access control.

                            Access Control Relay

                            RFID Radio Controls

                            We offer a range of RFID activation options. Activation at 1.5M, 3M and 5M ranges from the receiver.
                            • RFID Radio Controls

                              We offer a range of RFID activation options. Activation at 1.5M, 3M and 5M ranges from the receiver.

                              RFID Radio Controls

                              • Remote Control - Hold to run
                              • GSM Access
                              • Software/network connection
                              • Wind sensor
                              • Sun sensor
                              • Fire alarm activation

                              Activation Methods

                              The primary activation method for fire shutters is via the main fire alarm system. The signal from the fire alarm is routed via one of the below control units, giving the shutter a command to close.

                              In situations where there is no main fire alarm panel we can provide a standalone system that activates the fire alarm via one of the methods below as indicated with a * (please note for a standalone system an Audio Visual FDI panel is required).

                              Standard Fire Door Interface Panel

                              Supplied with all electric single phase shutters the unit transforms 240V power into safe 24V ensuring safety for the operator at all times. The unit is compliant with the Low Voltage Directive (LVD) The LED on the front of the panel has a colour code as follows:

                              • Amber when mains power is detected
                              • Green when opening the shutter
                              • Red when the shutter is closing
                              The control unit can also be connected via a continuous volt free signal to a fire alarm to open or close the shutter when the alarm is activated
                              • Standard Fire Door Interface Panel

                                Supplied with all electric single phase shutters the unit transforms 240V power into safe 24V ensuring safety for the operator at all times. The unit is compliant with the Low Voltage Directive (LVD) The LED on the front of the panel has a colour code as follows:

                                • Amber when mains power is detected
                                • Green when opening the shutter
                                • Red when the shutter is closing
                                The control unit can also be connected via a continuous volt free signal to a fire alarm to open or close the shutter when the alarm is activated

                                Standard Fire Door Interface Panel

                                FCP03 Audio Visual Panel

                                The FCP03 Fire Control Panel provides total control of commercial and industrial fire resisting roller shutter doors in the event of a fire. The FCP03 interfaces directly with the fire alarm on the premises and provides the fire-resisting roller shutter with the intelligence to close in the event of an emergency situation, protecting both occupants and premises from exposure to smoke and flame damage.
                                • FCP03 Audio Visual Panel

                                  The FCP03 Fire Control Panel provides total control of commercial and industrial fire resisting roller shutter doors in the event of a fire. The FCP03 interfaces directly with the fire alarm on the premises and provides the fire-resisting roller shutter with the intelligence to close in the event of an emergency situation, protecting both occupants and premises from exposure to smoke and flame damage.

                                  FCP03 Audio Visual Panel

                                  EMC3B Audio Visual Panel

                                  Principally this unit is designed to delay the closing of the fire shutter; generally the fire alarm is linked to the audio visual unit. There is no need for a separate relay; there is already a relay in the FDI. On activation from the fire alarm the unit starts to flash and sound, this unit contains a programmable timer which effectively delays the signal to the relay in the panel to close the door.
                                  • EMC3B Audio Visual Panel

                                    Principally this unit is designed to delay the closing of the fire shutter; generally the fire alarm is linked to the audio visual unit. There is no need for a separate relay; there is already a relay in the FDI. On activation from the fire alarm the unit starts to flash and sound, this unit contains a programmable timer which effectively delays the signal to the relay in the panel to close the door.

                                    EMC3B Audio Visual Panel

                                    Fusible Link

                                    Fusible links melt and activate the door system at a specific temperature.
                                    • Fusible Link

                                      Fusible links melt and activate the door system at a specific temperature.

                                      Fusible Link

                                      Smoke & Heat Detector

                                      Will send a signal to close upon detecting smoke or excessive heat.
                                      • Smoke & Heat Detector

                                        Will send a signal to close upon detecting smoke or excessive heat.

                                        Smoke & Heat Detector

                                        Peace of Mind Warranties

                                        All Guardian products are guaranteed against defect of material or workmanship by Guardian Doors, subject to correct maintenance and operation, for a period of 12 months from the date of installation. We offer extended warranties for up to 5 years with an agreed maintenance contract. Call us on 0800 7836602 for more details.

                                        Business Hours

                                        Monday - Friday
                                        8:00 to 17:00
                                        Saturday - Sunday
                                        Closed

                                        Our 24 hour emergency repair service is available every day - call 0800 7836602

                                        Privacy Policy & Cookies

                                        This website uses cookies that are necessary to its functioning and required to achieve the purposes illustrated in the privacy policy. By accepting this OR continuing to browse, you agree to our privacy policy.