E60-240
Commercial fire shutter model
The Guardian E60-240 fire resitant roller shutter provides a protective barrier in the event of a fire. They also double as a security shutter solution and are suitable for use every day.
All made to measure in the UK to the latest British and European standards the E60-240 is available with a 60, 120 or 240 minutes fire rating. We offer a range of control options for the activation of the shutter in the event of a fire as well as normal every day opening and closing.
Explanation of Fire Rating Symbols
Integrity & Insulation | |
E - Integrity | This is the ability of a test component to stop fire from spreading to an unexposed side as a result of penetration of flames or smoke. |
I - Insulation | This is the ability of a test component to restrict the temperature rise of the non-heated side to below specified levels during the fire, which is not more than +140°C up to +180°C. |
Integrity & Radiation Reduction | |
E - Integrity | This is the ability of a test component to stop fire from spreading to an unexposed side as a result of penetration of flames or smoke. |
W – Reduction of thermal radiation | This is the ability of a test component to resist fire exposure on one side only, so as to reduce the probability of the transmission of fire as a result of significant radiated heat either through the element or from its unexposed surface to neighbouring objects. |
All of the above parameters are followed by a time limit in minutes. The number after a given symbol shows the time the performance criteria is fulfilled during a standardised fire test, eg. EI120, EW60, etc.
Certifications
Tech Info
Standard Specification
Colour Finish
General Options

Protective Bollards

Angle Protection
Fitting Configurations
Safety

Warning Lights

Battery Backup

Reflected Photoelectric Cell

S/R Photoelectric Cell

Safety Pressure Edge Wired
Operation & Controls

Mushroom Push Button

Fire Brigade Switch

Push Buttons

Biometric Controls

Access Control Relay

Standard Fire Door Interface Panel

RFID Radio Controls
Activation Methods
The primary activation method for fire shutters is via the main fire alarm system. The signal from the fire alarm is routed via one of the below control units, giving the shutter a command to close.
In situations where there is no main fire alarm panel we can provide a standalone system that activates the fire alarm via one of the methods below as indicated with a * (please note for a standalone system an Audio Visual FDI panel is required).

Standard Fire Door Interface Panel

FCP03 Audio Visual Panel

EMC3B Audio Visual Panel

Smoke & Heat Detector*

Fusible Link*